手册
| 施乐 DC AP C7775 C6675 C5575 C4475 C3375 C3373 C2275 报错误 代码 005-913 |
| 施乐 维修呼叫报错误代码:005-913 |
| DADF Invert Sensor Static Jam (DADF-110) |
|
005-913 DADF Invert Sensor Static Jam (DADF-110)参照 FIPCF-001 参照FIP
CF-001 DADF Sensor Static Jam参考 BSD: CH5.10, CH5.3, CH5.12, CH5.5, CH5.13, CH5.16, CH5.4, CH5.11
Power On 时、Feeder Cover Interlock Close 时或 Platen Interlock Close 时 ·005-905 : DADF Feed Out Sensor (DADF-130 (1Pass)) ·005-906 : DADF Feed Out Sensor (DADF-110) ·005-906 : DADF Feed In Sensor (DADF-130 (1Pass)) ·005-907 : DADF Pre Regi. Sensor ·005-908 : DADF Regi. Sensor ·005-910 : DADF Out Sensor (DADF-130 (1Pass)) ·005-911 : DADF Exit Sensor (DADF-130 (1Pass)) ·005-913 : DADF Invert Sensor (DADF-110) ·005-915 : DADF APS Sensor 1 ·005-916 : DADF APS Sensor 2 ·005-917 : DADF APS Sensor 3
原因 / 处理1.检查相应Sensor 上的纸片残留、 异物、 执行器恢复不良或传感器脏污等
2.检查该Sensor 是否运作不良 · DADF Feed Out Sensor (DC330[005-205])(PL 51.6, PL 55.8) ·DADF Feed In Sensor (DC330[005-204])(PL 55.8) · DADF Pre Regi. Sensor (DC330[005-206])(PL 51.17, PL 55.17) · DADF Regi. Sensor (DC330[005-110])(PL 51.17, PL 55.17) · DADF Out Sensor (DC330[005-208])(PL 55.17) · DADF Exit Sensor (DC330[005-209])(PL 55.8) ·DADF Invert Sensor (DC330[005-211])(PL 51.9) · DADF APS Sensor 1 (DC330[005-218])(PL 51.17, PL 55.17) · DADF APS Sensor 2 (DC330[005-219])(PL 51.17, PL 55.17) · DADF APS Sensor 3 (DC330[005-220])(PL 51.17, PL 55.17)